Why CT is used in panel?

Published by Anaya Cole on

Why CT is used in panel?

Why to use a Protection Current Transformer with an Electrical Panel? The Protection Current Transformer is used to provide the currents to protection Relay. This is achieved by producing proportional currents in the unit’s secondary windings that remain isolated from the main circuit.

What is CT in panel?

A current transformer (CT) is a type of transformer that is used to reduce or multiply an alternating current (AC). It produces a current in its secondary which is proportional to the current in its primary.

What is difference between CT and PT?

A CT lowers the current signals for measurement purposes, while a PT lowers high voltage values into lower ones. The transformers are designed to measure whether power systems are both accurate and safe. In addition, the CT and PT transformer reduces the current and voltage from high to low value.

How is CT burden measured?

Burden of CT can be specified as Volt-Ampere absorbed at certain Power Factor i.e the VA that can be consumed by the load. The burden can also be expressed as total Impedance in terms of ohms connected on secondary of CT i.e. pilot conductor and instrument burden (I2 x R=VA).

What is CT and PT ratio?

CT is used to measure current while PT is used to measure voltage. CT is connected in series while PT is connected in parallel. CT ratio range is from 1 to 5A while the PT range is from 110V. We connect the output parameter from CT to the ampere meter while we connect the PT output to the voltmeter.

Why is PT connected in parallel?

Transformers are connected in series to increase the overall system voltage and are connected in parallel to be able to supply more current to the load, voltage remaining same.

What is a LT panel?

LT Panel is an electrical distribution board that receives power from generator or transformer and distributes the same to various electronic devices and distribution boards.

What is CT ratio?

The CT ratio is the ratio of primary current input to secondary current output at full load. For example, a CT with a ratio of 300:5 is rated for 300 primary amps at full load and will produce 5 amps of secondary current when 300 amps flow through the primary.

Why CT secondary is shorted?

The secondary side of the current transformer is always kept short-circuited in order to avoid core saturation and high voltage induction so that the current transformer can be used to measure high values of currents.

What is P1 and P2 in CT?

P1 indicates the side on which the current source is located, whilst P2 indicates the load side.

How do you Megger a CT?

Primary to Secondary: Connect the Red Lead of the Meggar to the CT Primary Stud and connect the Black Lead to the CT Secondary. In case of a Connected CT, remove the Secondary connections from the CT MK, and connect the Blck Lead of the Meggar to the each Secondary Core. Run the Test with 5 KV Test Voltage.

What is MF in electricity?

Multiplication Factor (MF) = (200×220 kV) / (1×110) = 400,000. Thus the difference of meter reading must be multiplied by the above Multiplication Factor to get the actual amount of energy imported / exported for our example.

What is burden in CT?

The burden of the CT is the resistive load used to create the voltage on the output. It varies with turns ratio, desired output and current rating of the primary.

Why is PT secondary grounded?

To prevent the secondary circuits from attaining dangerously high potential to ground, these circuits have to be grounded.

Why CT is grounded?

The grounding of current transformers is important to both safety and the proper operation of the protective relays. To assure the safe and reliable operation, the neutral of the current transformer secondary should have a single ground location for each circuit.

What is MCC and PCC panel?

MCC is motor control centre. In simple terms or generally a panel which supplies or received H.T power can be termed as PCC whereas panels which supplies power to L.T motors I.e those running on less than 415 volts are termed as MCC. They differ in protection relays and insulation category .

What is the PCC panel?

PCC (Power Control Centre) Panels are used to supervise and control the voltage and power of the power system. These panels are made of high-quality raw material and are extremely sturdy in fabrication.

How do I choose a CT ratio?

Important Points for Selecting a CT

  1. Current Transformer Output.
  2. Conductor Size.
  3. Load Size or Amperage Range.
  4. Accuracy Rating.
  5. Form Factor.
  6. Regulatory Requirements.
  7. Using Rogowski Coils.

What is P1 & P2 in CT?

CTs are marked with P1 and P2 to indicate which way they should be fitted around the cable or buss-bar. The side marked P1 must point towards the generator, and P2 must point towards the load. If an arrow is printed on the CT it must point towards the load.

Why CT secondary is 1A or 5A?

The standard CT secondary current ratings are 1A & 5A,The selection is based on the lead burden used for connecting the CT to meters/Relays. 5A CT can be used where Current Transformer & protectives device are located within same Switchgear Panel. 1A CT is preferred if CT leads goes out of the Switchgear.